The HT1000/2 is a high performance, full feature, hand held instrument designed to provide copper wire provisioning and maintenance technicians with the most critical tests at the touch of a button.
Durable and water resistant, the HT1000/2 is equipped with a highly effective 1/4 VGA LCD screen and a powerful backlight designed to make testing and troubleshooting easier in all work environments.
The on-screen menu launches most tests with a single keystroke.
Super Stress™ reaches beyond standard longitudinal balance testing, identifying even hard to find short loop unbalances.
Dual trace TDR is standard, with 12 trace storage and intermittent fault location.
The HT1000/2 has user selectable auto tests with an incremental pair testing process.
Test for DC and AC volts at the same time, no need to switch between separate screens.
Download updates and upload test results quickly and easily via the integrated USB port.
Easy to navigate and launch testing; many of the standard 26 tests begin with the push of a single button: either from the numeric keypad, or the soft key navigation pad.
(Model HT1000/2A unless otherwise stated)
General
ACV:
0 V to 200 V (±2%, ± 1 V)
DCV:
0 V to ±200 V (±2%, ±1 V)
Resistance:
0 Ω to 1,000 KΩ (±2%, ±1 Ω)
Leakage:
1 MΩ to 999 MΩ (±3%), 150 V open circuit output
Longitudinal balance
+30 dBrn to +80 dBrn (±2 dBrn)
Super Stress™:
-10 dBrn to +30 dBrn (±2 dBrn)
Load coil detection:
0 coil to 4 coils (±1 coil)
Loop current:
0 mA to ±100 mA (±2%, ±1 mA)
Power influence:
+40 dBrnC to +100 dBrnC (±2 dBrnC)
Noise (Voice Band):
0 dBrnC to +60 dBrnC (±2 dBrnC)
Loss (Voice Band):
-40 dBm to +10 dBm (±1 dBm)
Open meter:
0 m (0 ft) to 900 m (3,000 ft) ±2%, ±1.5 m (5ft) 900 m (3,000 ft) to 15 km (50,000 ft) (±3%)
Auto test:
7 user-selectable auto test scripts, 200 pair storage, retest capability, Incremental pair testing program
ID tone
Frequency: 577.5 Hz (±1%) Amplitude: 0 dBm, 600 Ω (±1 dBm)
Caller ID:
Yes
Wideband tone send:
Frequency: 20 KHz to 9 MHz (±1%) Amplitude: 0 dBm, 135 Ω (±1 dBm)
Wideband tone receive:
Frequency: 20 KHz to 33 MHz Amplitude: -90 dBm, +2 dBm (±2 dBm)
Wideband loss:
Frequency: 20 KHz to 33 MHz Amplitude: -90 dBm, +2 dBm (±2 dBm) RFL Distance to fault: 0 – 3.000 m (10,000 ft) ±0.5%, ±1 m (3 ft) Maximum measurable fault resistance: 100 MΩ Maximum locatable fault resistance: 2 MΩ
TDR:
Dual trace, 12 trace memory storage, Automatic pulse width selection, Pair comparison mode, Split/crosstalk mode, Intermittent fault location, Closest range 0 – 8 m (25 ft), Longest range 0 – 16.000 m (49,000 ft) (@VOP = 0.7), Zoom mode
Wideband spectrum analyzer:
Frequency: 20 KHz to 33 MHz Amplitude: -90 dBm to +10 dBm (±2 dBm) -130 dBm/Hz to -30 dBm/Hz (±2 dBm/Hz)
Impulse noise:
Amplitude: -45 dBm to +10 dBm (±2 dBm) Filters: F, G, J, None (30 MHz)
Voiceband spectrum analyzer:
Frequency: 50 Hz to 4,100 Hz Amplitude: -64 dBm to 0 dBm (±2 dBm) -76 dBm/Hz to -12 dBm/Hz (±2 dBm/Hz)
Display:
High resolution, ¼ VGA graphics with LED backlight
Instrument
Batteries:
Rechargeable nickel-metal hydride
Battery Life:
Approximately 30 hours typical usage
Weight:
0.8 kg (28 oz)
Dimensions:
254 mm x 114.3 mm x 63.5 mm (10” x 4.5” x 2.5”)
Environmental:
Weather and drop resistant in accordance with MIL-STD-810F
Standards compliance:
VDSL2 G.993.2 Bandplans: 8, 12, 17, 30 MHz Profiles: 8a, 8b, 8c, 8d, 12a, 12b, 17a, 30a Plan 997, Plan 998 Capable of emulating a CO/DSLAM
HT1000/2C (VDSL2) Specifications
In addition to features of HT1000/2A
Standards compliance:
VDSL2 G.993.2 Bandplans: 8, 12, 17, 30 MHz Profiles: 8a, 8b, 8c, 8d, 12a, 12b, 17a, 30a Plan 997, Plan 998 Capable of emulating a CO/DSLAM
Link statistics:
Connection Type (VDSL2, RT, CO)
HPNA Specifications
In addition to features of HT1000/2C
Standards compliance:
ITU G.9954 (Home PNA 3.1)
Parameters measured:
Phy - Physical connection rate PER - Packet error rate SNR - Signal to noise ratio Attn - Attenuation
|
Test Lead set Red/Black
A replacement test lead set for use with the HT1000/2. This leadset is 250mm long with Croc Clips for connectivity.
|
2003-369
|
|
|
|
Test Lead set Green/Yellow
A replacement test lead set for use with the HT1000/2. This leadset is 250mm long with Croc Clips for connectivity.
|
2003-370
|
|
|
|
AC charger
Allows the use of the HT1000/2 whist plugged in to an AC source such as the mains. Instrument also charges whist in use.
|
2001-697
|
|
|
|
Soft carrying case
A padded, secure storage case for your HT1000/2 to keep it safe from knocks and retain all parts in one place.
|
1001-2001
|
|
|
|
DC charger
Allows the use of the HT1000/2 whist plugged in to a DC source such as a car cigarette lighter socket. Instrument also charges whist in use.
|
1001-2025
|
|
|
|
USB cord
Enables the HT1000/2 to be connected to a PC for data downloading and updates.
|
1001-2015
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
HT1000/2 Data Sheet
|
130 KB |
|
| User Guide |
| |
HT1000/2 User Guide
|
87 KB |
|
| |
|
|
|