DLRO10HD Product Page
|
|
Unidirectional, automatic, continuous and inductive modes
Rated CAT III 300 V
Operational ingress protection is IP 54
High or low output power selection
Large clear backlit LCD display
Auto power off function conserves battery
Augmenting Megger's DLRO10 and 10X range the DLRO10HD combines ultimate simplicity of operation with a rugged IP65 case designed for stable ground and bench operation.
The unit is powered from either its rechargeable battery or line power making it suitable for continuous testing in production line/repetitive use environments.
Rotary switch controls are simple and easy to operate in all weather conditions and with gloved hands. A large, clear, backlit LCD display is easy to read from a
distance. The DLRO10HD provides significantly enhanced compliance and is capable of delivering 10 A into measurements up to 250 mΩ and 1A into measurements up to 2.5Ω.
The duration of each test may be up to 60 seconds.
The DLRO10HD is rated CAT III 300 V. A range of test leads is available to suit the application.
The DLRO10HD provides five test modes each of which is selected through a simple rotary control.
Specification:
Temperature Coefficient: 0.01% per ºC, from 5 ºC to 40 ºC
Maximum Altitude: 2000m (6562 ft) to full safety specifications
Display size/type: Main 5 digit + 2 x 5 digitsecondary displays
Battery type: 6 V, 7Ah sealed lead acid
Voltage input range 90 - 264 V, 50-60 Hz
Charge time: 8 hours
Backlight:LED backlight
Battery life:1000 Auto (3 sec) tests
Auto power down: 300s
Mode Selection: Rotary switch
Range selection: Rotary switch
Weight: 6.7kg
Case dimensions: L315mm x W285mm x H181mm
Pouch for test leads Yes (lid mounted)
Test leads: DH4 lead set included
IP rating: IP65 case closed, IP54 battery operation
Safety rating: In accordance with IEC61010-1, CATIII 300 V when used with DH7 leads
Operating temperature and humidity:-10 °C to +50 °C (14 °F to 122 °F) <90% RH
Reference conditions: 20 °C ±3 °C
Storage temperature and humidity: -25 °C to +60 °C, <90% RH
EMC: In accordance with IEC61326-1 (Heavy industrial)
Noise rejection: Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level.
Maximum lead resistance:100 mΩ total for 10 A operation irrespective of battery condition.
Included Accessories
|
DH4 duplex handspike 1.2m.
|
6111-503
|
|
|
|
Test lead pouch (lid mounted).
|
1000-036
|
|
|
|
DLRO10HD user guide CD.
|
1000-869
|
|
|
Optional Accessories
|
|
|
Calibration Shunt,10Ω, current rating 1 mA.
|
249000
|
|
|
|
Calibration Shunt, 1Ω, current rating 10 mA.
|
249001
|
|
|
|
Calibration Shunt, 100 mΩ current rating 1A.
|
249002
|
|
|
|
Calibration Shunt, 10 mΩ current rating 10 A.
|
249002
|
|
|
|
Certificate of Calibration for Shunts, NIST.
|
CERT-NIST
|
|
|
|
Replacement tips for DH4, DH5 and DH7 handspikes. - Needle point.
|
25940-012
|
|
|
|
Replacement tips for DH4, DH5 and DH7 handspikes. - Serrated end.
|
25940-014
|
|
|
Optional Test Leads (Qty)
|
|
|
Duplex Lead - DH5 straight duplex handspikes (2).
One has indicator lights. 2.5m/8ft
|
25940-014
|
|
|
|
DH7 Duplex handspikes (2).
Suitable for working on 600 V systems. 2.5m/8ft
|
1001-035
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
2m/7ft
|
242011-7
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
2.5m/8ft
|
6111-022
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
5.5m/18ft
|
242011-18
|
|
|
|
DH2 - Duplex Handspikes (1) with spring loaded helical contacts.
6m/20ft
|
242011-18
|
|
|
|
DH2 - Duplex Handspikes (1) with spring loaded helical contacts.
9m/30ft
|
242011-30
|
|
|
|
DH3 - Duplex Handspikes (1) with spring loaded helical contacts.
9m/30ft
|
6111-024
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
2m/7ft
|
242002-7
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
5.5m/18ft
|
242002-18
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
9m/30ft
|
242002-30
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
2m/7ft
|
242004-7
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
5.5m/18ft
|
242004-18
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
9m/30ft
|
242004-30
|
|
|
|
Duplex handspikes with replaceable needle points.
2m/7ft
|
242003-7
|
|
|
|
Duplex 1.27 cm (1/2 “) Kelvin Clips. (2).
gold plated. 2m/7ft
|
241005-7
|
|
|
|
Duplex 1.27 cm (1/2 “) Kelvin Clips. (2).
silver plated. 2m/7ft
|
242005-7
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
2m/7ft
|
242006-7
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
5.5m/18ft
|
242006-18
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
9m/30ft
|
242006-30
|
|
|
|
Single handspike (1) for potential measurement.
2m/7ft
|
242021-7
|
|
|
|
Single handspike (1) for potential measurement.
5.5m/18ft
|
242021-18
|
|
|
|
Single handspike (1) for potential measurement.
9m/30ft
|
242021-30
|
|
|
|
Current clip (1) for current connections.
2m/7ft
|
242041-7
|
|
|
|
Current clip (1) for current connections.
5.5m/18ft
|
242041-18
|
|
|
|
Current clip (1) for current connections.
9m/30ft
|
242041-30
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
DLRO10HD Data Sheet
|
470 KB |
|
| User Guide |
| |
DLRO10HD User Guide
|
438 KB |
|
|
|
|
|
INTRODUCING THE DLRO10HD
Unidirectional, automatic, continuous and inductive modes
Rated CAT III 300 V
Operational ingress protection is IP 54
High or low output power selection
Large clear backlit LCD display
Auto power off function conserves battery
Augmenting Megger's DLRO10 and 10X range the DLRO10HD combines ultimate simplicity of operation with a rugged IP65 case designed for stable ground and bench operation.
The unit is powered from either its rechargeable battery or line power making it suitable for continuous testing in production line/repetitive use environments.
Rotary switch controls are simple and easy to operate in all weather conditions and with gloved hands. A large, clear, backlit LCD display is easy to read from a
distance. The DLRO10HD provides significantly enhanced compliance and is capable of delivering 10 A into measurements up to 250 mΩ and 1A into measurements up to 2.5Ω.
The duration of each test may be up to 60 seconds.
The DLRO10HD is rated CAT III 300 V. A range of test leads is available to suit the application.
The DLRO10HD provides five test modes each of which is selected through a simple rotary control.
Specification:
Temperature Coefficient: 0.01% per ºC, from 5 ºC to 40 ºC
Maximum Altitude: 2000m (6562 ft) to full safety specifications
Display size/type: Main 5 digit + 2 x 5 digitsecondary displays
Battery type: 6 V, 7Ah sealed lead acid
Voltage input range 90 - 264 V, 50-60 Hz
Charge time: 8 hours
Backlight:LED backlight
Battery life:1000 Auto (3 sec) tests
Auto power down: 300s
Mode Selection: Rotary switch
Range selection: Rotary switch
Weight: 6.7kg
Case dimensions: L315mm x W285mm x H181mm
Pouch for test leads Yes (lid mounted)
Test leads: DH4 lead set included
IP rating: IP65 case closed, IP54 battery operation
Safety rating: In accordance with IEC61010-1, CATIII 300 V when used with DH7 leads
Operating temperature and humidity:-10 °C to +50 °C (14 °F to 122 °F) <90% RH
Reference conditions: 20 °C ±3 °C
Storage temperature and humidity: -25 °C to +60 °C, <90% RH
EMC: In accordance with IEC61326-1 (Heavy industrial)
Noise rejection: Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level.
Maximum lead resistance:100 mΩ total for 10 A operation irrespective of battery condition.
Included Accessories
|
DH4 duplex handspike 1.2m.
|
6111-503
|
|
|
|
Test lead pouch (lid mounted).
|
1000-036
|
|
|
|
DLRO10HD user guide CD.
|
1000-869
|
|
|
Optional Accessories
|
|
|
Calibration Shunt,10Ω, current rating 1 mA.
|
249000
|
|
|
|
Calibration Shunt, 1Ω, current rating 10 mA.
|
249001
|
|
|
|
Calibration Shunt, 100 mΩ current rating 1A.
|
249002
|
|
|
|
Calibration Shunt, 10 mΩ current rating 10 A.
|
249002
|
|
|
|
Certificate of Calibration for Shunts, NIST.
|
CERT-NIST
|
|
|
|
Replacement tips for DH4, DH5 and DH7 handspikes. - Needle point.
|
25940-012
|
|
|
|
Replacement tips for DH4, DH5 and DH7 handspikes. - Serrated end.
|
25940-014
|
|
|
Optional Test Leads (Qty)
|
|
|
Duplex Lead - DH5 straight duplex handspikes (2).
One has indicator lights. 2.5m/8ft
|
25940-014
|
|
|
|
DH7 Duplex handspikes (2).
Suitable for working on 600 V systems. 2.5m/8ft
|
1001-035
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
2m/7ft
|
242011-7
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
2.5m/8ft
|
6111-022
|
|
|
|
DH1 - Duplex Handspikes (2) with spring loaded helical contacts.
5.5m/18ft
|
242011-18
|
|
|
|
DH2 - Duplex Handspikes (1) with spring loaded helical contacts.
6m/20ft
|
242011-18
|
|
|
|
DH2 - Duplex Handspikes (1) with spring loaded helical contacts.
9m/30ft
|
242011-30
|
|
|
|
DH3 - Duplex Handspikes (1) with spring loaded helical contacts.
9m/30ft
|
6111-024
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
2m/7ft
|
242002-7
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
5.5m/18ft
|
242002-18
|
|
|
|
Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.
9m/30ft
|
242002-30
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
2m/7ft
|
242004-7
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
5.5m/18ft
|
242004-18
|
|
|
|
Duplex Heavy Duty 5cm (2”) C-Clamps. (2)
9m/30ft
|
242004-30
|
|
|
|
Duplex handspikes with replaceable needle points.
2m/7ft
|
242003-7
|
|
|
|
Duplex 1.27 cm (1/2 “) Kelvin Clips. (2).
gold plated. 2m/7ft
|
241005-7
|
|
|
|
Duplex 1.27 cm (1/2 “) Kelvin Clips. (2).
silver plated. 2m/7ft
|
242005-7
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
2m/7ft
|
242006-7
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
5.5m/18ft
|
242006-18
|
|
|
|
Duplex 3.8 cm (11/2”) Kelvin Clips. (2).
9m/30ft
|
242006-30
|
|
|
|
Single handspike (1) for potential measurement.
2m/7ft
|
242021-7
|
|
|
|
Single handspike (1) for potential measurement.
5.5m/18ft
|
242021-18
|
|
|
|
Single handspike (1) for potential measurement.
9m/30ft
|
242021-30
|
|
|
|
Current clip (1) for current connections.
2m/7ft
|
242041-7
|
|
|
|
Current clip (1) for current connections.
5.5m/18ft
|
242041-18
|
|
|
|
Current clip (1) for current connections.
9m/30ft
|
242041-30
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
DLRO10HD Data Sheet
|
470 KB |
|
| User Guide |
| |
DLRO10HD User Guide
|
438 KB |
|
|
|
|
|
INTRODUCING THE DLRO10HD
|
|
|
 |
|
 |
|
|