DCM340 Product Page
|
|
DC and AC current and voltage
600 A and 600 V
Resistance and continuity
3½ digit, 4000 count display with backlight
High resolution digital bargraph
Data hold feature
Peak, min/max hold
The DCM340 is a highly versatile instrument and ideal for use in the installation, maintenance, monitoring or checking of a.c. or d.c. electrical systems and equipment.
There are four instruments in the DCM series, including the 400 A a.c. current-only DCM310; the DCM320 which includes voltage and resistance measurement; the DCM330
Fork-Multimeter, which is an open fixed jaw design; and this, the DCM340. Capable of measuring a.c. and d.c. current up to 600 A; a.c. and d.c. voltage up to 600 V;
resistance up to 400 ; and frequency up to 400 Hz, the DCM340 is the most versatile in the range.
Current measurement combined with the comprehensive and accurate multimeter functions of the DCM340 eliminate the need to carry around both a clampmeter and multimeter - this
instrument does it all.
The large clear digits of the numeric display are complemented by the high-resolution digital bar graph, useful for indicating trending and fluctuation of measurement.
The backlight assists use in poorly lit areas such as distribution cupboards and corners of switchrooms; and the data-hold feature enables use on difficult access cables
where otherwise the display may be impossible to see. Min/Max hold provides the ability to store the maximum and minimum d.c. or rms values over a period of time. While storage
is taking place, either the present, maximum or minimum value can be displayed. Peak hold stores the maximum and minimum peak value of an a.c. signal at a 10 ms sample rate. The auto-off
feature automatically places the meter in power-save mode after 30 minutes from power-on, but this can be disabled if required for min/max measurements.
Using the Relative mode (REL), a stable value can be stored, the instrument zeroed at that point, and then any variation from that value is displayed as a direct measurement relative
to it.
The DCM340 is safety rated to IEC 61010-1 Cat III 600 V, and is drop-tested to 1.2 m onto a hard floor. It is supplied with test leads and a carry case, and a full 1-year manufacturer's
warranty.
Base specifications only. For detailed specification, refer to User Guide All accuracies specified at 23°C ±5° <80%Rh
AC Current
|
Range
|
50 - 60Hz
|
61 - 400Hz
|
|
0-60.0 A
|
±1.9% ±7 digits
|
±2.5% ±7 digits
|
|
60.0 - 400.0 A
|
±1.9% ±5 digits
|
±2.5% ±5 digits
|
|
400 - 600 A
|
±2.5% ±5 digits
|
±2.9% ±5 digits
|
DC Current
|
Range
|
Accuracy
|
|
0 - 60.0A
|
±1.5% ±10 digits
|
|
60.0 - 400.0A
|
±1.9% ±5 digits
|
|
400 - 600 A
|
±1.9% ±10 digits
|
Voltage
|
Range
|
50 - 500Hz Accuracy
|
DC Accuracy
|
|
0 - 400.0 V
|
±1.0% ±5 digits
|
±0.7% ±2 digits
|
|
400 - 600 V
|
±1.0% ±5 digits
|
±0.7% ±2 digits
|
|
Input impedance:
|
1 MΩ // < 100pF
|
|
Resistance & Continuity
|
Range
|
Accuracy
|
|
0 - 400.0Ω
|
±1% ±3 digits
|
|
Open circuit voltage:
|
3 V
|
|
Continuity Check:
|
beeper sounds @ < 30Ω
|
Frequency
|
Range
|
Resolution
|
Accuracy
|
|
20 - 400 Hz
|
1 Hz
|
±0.1 % ±2 digtits
|
General
Sensitivity: 3 A
Peak Hold: ±3% ±15 digits
Sample time: 10 ms
MIN/MAX Hold: add 15 digits to accuracy for a.c. & d.c.
Positional error: ±1% of reading
Overload protection:600 V & 600 A rms
AC conversion: Average sensing rms indication calibrated to the rms value of a sine wave input
Auto power-off: 30 minutes after power-on
LCD
Display: 31/2 digit large-scale readout
Count: 40,000
Sample Rate: 1.5 per second
Overrange: “OL”
Power Requirement
1 x 9V PP3 MN1604 6LR61 alkaline cell
Battery life: 200 hours (alkaline)
Operating Temperature
0°C - 30°C <80% Rh
30°C - 40°C <75% Rh
400°C - 50°C <45% Rh
Storage Temperature
-20°C - +60°C (<81% Rh)
(batteries removed)
Safety
Overvoltage safety category: IEC 61010-1 600V CAT III
Operating Altitude: 2000 m
Drop-protection: 1.2 m onto a hardwood surface
Jaw size/maximum conductor: 35 mm diameter
Calibration period: 12 month recommended
Dimensions: 68 mm (W) x 237 mm (H) x 42 mm (D)
Weight: 225 g including batteries
|
Red/black test leads with croc clips
|
1001-858
|
|
|
|
Red/black fused test leads (500 mA) with croc clips
|
1002-015
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
DCM340 Data Sheet
|
130 KB |
|
| User Guide |
| |
DCM340 User Guide
|
86.6 KB |
|
| |
|
|
|
INTRODUCING THE DCM340
DC and AC current and voltage
600 A and 600 V
Resistance and continuity
3½ digit, 4000 count display with backlight
High resolution digital bargraph
Data hold feature
Peak, min/max hold
The DCM340 is a highly versatile instrument and ideal for use in the installation, maintenance, monitoring or checking of a.c. or d.c. electrical systems and equipment.
There are four instruments in the DCM series, including the 400 A a.c. current-only DCM310; the DCM320 which includes voltage and resistance measurement; the DCM330
Fork-Multimeter, which is an open fixed jaw design; and this, the DCM340. Capable of measuring a.c. and d.c. current up to 600 A; a.c. and d.c. voltage up to 600 V;
resistance up to 400 ; and frequency up to 400 Hz, the DCM340 is the most versatile in the range.
Current measurement combined with the comprehensive and accurate multimeter functions of the DCM340 eliminate the need to carry around both a clampmeter and multimeter - this
instrument does it all.
The large clear digits of the numeric display are complemented by the high-resolution digital bar graph, useful for indicating trending and fluctuation of measurement.
The backlight assists use in poorly lit areas such as distribution cupboards and corners of switchrooms; and the data-hold feature enables use on difficult access cables
where otherwise the display may be impossible to see. Min/Max hold provides the ability to store the maximum and minimum d.c. or rms values over a period of time. While storage
is taking place, either the present, maximum or minimum value can be displayed. Peak hold stores the maximum and minimum peak value of an a.c. signal at a 10 ms sample rate. The auto-off
feature automatically places the meter in power-save mode after 30 minutes from power-on, but this can be disabled if required for min/max measurements.
Using the Relative mode (REL), a stable value can be stored, the instrument zeroed at that point, and then any variation from that value is displayed as a direct measurement relative
to it.
The DCM340 is safety rated to IEC 61010-1 Cat III 600 V, and is drop-tested to 1.2 m onto a hard floor. It is supplied with test leads and a carry case, and a full 1-year manufacturer's
warranty.
Base specifications only. For detailed specification, refer to User Guide All accuracies specified at 23°C ±5° <80%Rh
AC Current
|
Range
|
50 - 60Hz
|
61 - 400Hz
|
|
0-60.0 A
|
±1.9% ±7 digits
|
±2.5% ±7 digits
|
|
60.0 - 400.0 A
|
±1.9% ±5 digits
|
±2.5% ±5 digits
|
|
400 - 600 A
|
±2.5% ±5 digits
|
±2.9% ±5 digits
|
DC Current
|
Range
|
Accuracy
|
|
0 - 60.0A
|
±1.5% ±10 digits
|
|
60.0 - 400.0A
|
±1.9% ±5 digits
|
|
400 - 600 A
|
±1.9% ±10 digits
|
Voltage
|
Range
|
50 - 500Hz Accuracy
|
DC Accuracy
|
|
0 - 400.0 V
|
±1.0% ±5 digits
|
±0.7% ±2 digits
|
|
400 - 600 V
|
±1.0% ±5 digits
|
±0.7% ±2 digits
|
|
Input impedance:
|
1 MΩ // < 100pF
|
|
Resistance & Continuity
|
Range
|
Accuracy
|
|
0 - 400.0Ω
|
±1% ±3 digits
|
|
Open circuit voltage:
|
3 V
|
|
Continuity Check:
|
beeper sounds @ < 30Ω
|
Frequency
|
Range
|
Resolution
|
Accuracy
|
|
20 - 400 Hz
|
1 Hz
|
±0.1 % ±2 digtits
|
General
Sensitivity: 3 A
Peak Hold: ±3% ±15 digits
Sample time: 10 ms
MIN/MAX Hold: add 15 digits to accuracy for a.c. & d.c.
Positional error: ±1% of reading
Overload protection:600 V & 600 A rms
AC conversion: Average sensing rms indication calibrated to the rms value of a sine wave input
Auto power-off: 30 minutes after power-on
LCD
Display: 31/2 digit large-scale readout
Count: 40,000
Sample Rate: 1.5 per second
Overrange: “OL”
Power Requirement
1 x 9V PP3 MN1604 6LR61 alkaline cell
Battery life: 200 hours (alkaline)
Operating Temperature
0°C - 30°C <80% Rh
30°C - 40°C <75% Rh
400°C - 50°C <45% Rh
Storage Temperature
-20°C - +60°C (<81% Rh)
(batteries removed)
Safety
Overvoltage safety category: IEC 61010-1 600V CAT III
Operating Altitude: 2000 m
Drop-protection: 1.2 m onto a hardwood surface
Jaw size/maximum conductor: 35 mm diameter
Calibration period: 12 month recommended
Dimensions: 68 mm (W) x 237 mm (H) x 42 mm (D)
Weight: 225 g including batteries
|
Red/black test leads with croc clips
|
1001-858
|
|
|
|
Red/black fused test leads (500 mA) with croc clips
|
1002-015
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
DCM340 Data Sheet
|
130 KB |
|
| User Guide |
| |
DCM340 User Guide
|
86.6 KB |
|
| |
|
|
|
INTRODUCING THE DCM340
|
|
|
 |
|
 |
|
|