REGISTER  |  LOGIN
 DET14/DET24C Product Page
Auto-current measurement safety feature
Memory to record and view results
Measure ground resistance 0.05Ω-15KΩ
Memory to record and view results
Measures true RMS ground leakage
CAT IV 600 V safety rating
Backlit LCD display
The DET14C and DET24C represent a new generation of earth/ground clamp-on resistance testers. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. They offer market leading access, advanced features, simple operation and CAT IV 600 V safety protection.

Designed with flat core ends they prevent dirt build up, ensuring measurement integrity and improved reliability over products with interlocking teeth. Other enhancements over current generation products include improved accuracy and up to 300% increase in battery life. In electrically noisy environments the built-in filter function offers increased noise immunity.

DET14C and DET24C also offer a true RMS AC current measurement facility up to 35 Amps. The instrument's ability to measure current flowing in an earth cable is a useful safety feature, especially if the earth cable has to be disconnected. A high current flow to earth could draw an arc on dis-connection with potentially severe consequences.

The elliptical shaped head design offers improved access to cables and earth straps in space constrained locations. The clamp head accommodates up to 37 mm diameter cable and 50 mm earth tapes making them suitable for use in power stations, substations, towers and many more facilities. Operation in dark and restricted areas is facilitated by a display with backlight and an audible tone associated with the hold key. Optimised jaw opening mechanism ensures proper jaw closure without excessive use of force when opening the jaws.

The DET14C offers storage of results for later on-screen recall and the DET24C supports a download of results via IrDA-to-USB link into PowerDB and Power DB Lite, Megger's acceptance and maintenance test data management software. Stored data is indexed using a sequential reference number together with a time and date stamp for each record.
INTRODUCING THE DET14C & DET24C
Auto-current measurement safety feature
Memory to record and view results
Measure ground resistance 0.05Ω-15KΩ
Memory to record and view results
Measures true RMS ground leakage
CAT IV 600 V safety rating
Backlit LCD display
The DET14C and DET24C represent a new generation of earth/ground clamp-on resistance testers. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. They offer market leading access, advanced features, simple operation and CAT IV 600 V safety protection.

Designed with flat core ends they prevent dirt build up, ensuring measurement integrity and improved reliability over products with interlocking teeth. Other enhancements over current generation products include improved accuracy and up to 300% increase in battery life. In electrically noisy environments the built-in filter function offers increased noise immunity.

DET14C and DET24C also offer a true RMS AC current measurement facility up to 35 Amps. The instrument's ability to measure current flowing in an earth cable is a useful safety feature, especially if the earth cable has to be disconnected. A high current flow to earth could draw an arc on dis-connection with potentially severe consequences.

The elliptical shaped head design offers improved access to cables and earth straps in space constrained locations. The clamp head accommodates up to 37 mm diameter cable and 50 mm earth tapes making them suitable for use in power stations, substations, towers and many more facilities. Operation in dark and restricted areas is facilitated by a display with backlight and an audible tone associated with the hold key. Optimised jaw opening mechanism ensures proper jaw closure without excessive use of force when opening the jaws.

The DET14C offers storage of results for later on-screen recall and the DET24C supports a download of results via IrDA-to-USB link into PowerDB and Power DB Lite, Megger's acceptance and maintenance test data management software. Stored data is indexed using a sequential reference number together with a time and date stamp for each record.
INTRODUCING THE DET14C & DET24C
  
  
Legal | Privacy Find us on Facebook Follow us on Twitter Download Acrobat Reader Copyright © Megger Limited 2011

AVO, BIDDLE, MEGGER, MULTI-AMP, PAX Diagnostics, POWERDB, PROGRAMMA, and STATES are trademarks or registered trade marks of subsidiaries of Megger Group Limited

Legal | Privacy Find us on Facebook Follow us on Twitter Download Acrobat Reader Copyright © Megger Limited 2011

AVO, BIDDLE, MEGGER, MULTI-AMP, PAX Diagnostics, POWERDB, PROGRAMMA, and STATES are trademarks or registered trade marks of subsidiaries of Megger Group Limited