 MIT410/MIT430 Product Page
CAT IV 600 V applications
TRMS & DC Voltage measurement
Insulation testing to 1000V and 200GΩ
Continuity testing at 200mA or 20mA down to 0.01Ω
Pass/Fail limit alarms
Analogue and dual digital display
PI/DAR and Timer function
The new Megger MIT400 series of insulation and continuity testers has been designed for electrical testing by the utilities, industrial, commercial and domestic electricians. The wide range of features also makes the MIT400 series ideal for maintenance and service/repair engineers. They give greater functionality than previous instruments, with simplified operation, wider range of applications and increased safety.

MIT410-TC2: 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR
MIT430-TC2: 50 V 100 V, 250 V, 500 V & 1000 V + Bluetooth Download

Insulation Testing

Test voltages - 250 V to 1000 V or 50 V to 1000 V insulation test voltages available

Test Lock - Locks insulation test on continuously

Test voltage display - The actual test voltage is displayed on the smaller digital readout, with the insulation result on the larger digital display.

Analogue arc - The display also features an analogue arc to replicate the response of a moving coil display.

PI and DAR - Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions.

Silicone leads - High quality flexible silicone test leads are comfortable to use and prevent measurement errors on higher GΩ ranges.

Test inhibit - prevents testing if voltages in excess of 50 V are detected when making insulation tests.

Insulation buzzer - The buzzer can be set to buzz if the insulation resistance is above a preset limit, set via the setup menu.

Continuity Testing

Auto test - Auto test on circuit contact enables real two handed operation without the need to press the test button

200 mA or 20 mA- Either 200 mA or 20 mA continuity test currents are available. 20 mA test current will considerably increase battery life

Lead null - Lead resistance compensation (NULL) operates up to 9.99Ω of resistance.

Buzzer - ON-OFF selected by simple push button.

Buzzer limit - Continuity buzzer limit alarm provides adjustment of the maximum resistance the continuity buzzer sounds. This is adjustable from 1Ω to 20Ω in 5 steps.

kΩ range - extends resistance measurement to 1 MΩ.

Display

The display offers a combination of analogue arc and a dual digital readout

Analogue arc:

Full display width analogue arc.

Patented arc display shows essential charge and discharge characteristics not visible on a digital display.

Single pointer "needle" response is similar to a moving coil meter.

Logarithmic display for better low insulation value measurements.

Dual digital display:

Large main digital readout for good visibility of all main measurement results.

Second digital display for additional data such as:

Insulation test voltage.

Insulation leakage current.

Supply frequency (when measuring volts).

Test mode eg. PI, DAR or TI (Timed mode).

Storage & Downloading Results

MIT430

The MIT430 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software. Data transfer is by Bluetooth.

NOTE: The receiving PC needs to have Bluetooth capability or a USB port fitted a Bluetooth receiver. Class II (10m) is acceptable.

Safety

Designed to be exceptionally safe to use, fast detecting circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Specifically, all instruments:
Meet the international requirements of IEC1010-2 and EN61557.

Live circuit detection inhibits insulation testing on circuits above 50 V.

Live circuit detection and test inhibit on continuity measurements.

Default display of live circuit voltage on all ranges.

Detection and inhibit functions operate even if the protection fuse has failed.

Suitable for use on CAT IV applications and supply voltages to 600 V


600 V CAT IV

All MIT400 instruments are designed to meet the safety requirements for use on CAT IV 600 V
INTRODUCING THE MIT400 SERIES
CAT IV 600 V applications
TRMS & DC Voltage measurement
Insulation testing to 1000V and 200GΩ
Continuity testing at 200mA or 20mA down to 0.01Ω
Pass/Fail limit alarms
Analogue and dual digital display
PI/DAR and Timer function
The new Megger MIT400 series of insulation and continuity testers has been designed for electrical testing by the utilities, industrial, commercial and domestic electricians. The wide range of features also makes the MIT400 series ideal for maintenance and service/repair engineers. They give greater functionality than previous instruments, with simplified operation, wider range of applications and increased safety.

MIT410-TC2: 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR
MIT430-TC2: 50 V 100 V, 250 V, 500 V & 1000 V + Bluetooth Download

Insulation Testing

Test voltages - 250 V to 1000 V or 50 V to 1000 V insulation test voltages available

Test Lock - Locks insulation test on continuously

Test voltage display - The actual test voltage is displayed on the smaller digital readout, with the insulation result on the larger digital display.

Analogue arc - The display also features an analogue arc to replicate the response of a moving coil display.

PI and DAR - Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions.

Silicone leads - High quality flexible silicone test leads are comfortable to use and prevent measurement errors on higher GΩ ranges.

Test inhibit - prevents testing if voltages in excess of 50 V are detected when making insulation tests.

Insulation buzzer - The buzzer can be set to buzz if the insulation resistance is above a preset limit, set via the setup menu.

Continuity Testing

Auto test - Auto test on circuit contact enables real two handed operation without the need to press the test button

200 mA or 20 mA- Either 200 mA or 20 mA continuity test currents are available. 20 mA test current will considerably increase battery life

Lead null - Lead resistance compensation (NULL) operates up to 9.99Ω of resistance.

Buzzer - ON-OFF selected by simple push button.

Buzzer limit - Continuity buzzer limit alarm provides adjustment of the maximum resistance the continuity buzzer sounds. This is adjustable from 1Ω to 20Ω in 5 steps.

kΩ range - extends resistance measurement to 1 MΩ.

Display

The display offers a combination of analogue arc and a dual digital readout

Analogue arc:

Full display width analogue arc.

Patented arc display shows essential charge and discharge characteristics not visible on a digital display.

Single pointer "needle" response is similar to a moving coil meter.

Logarithmic display for better low insulation value measurements.

Dual digital display:

Large main digital readout for good visibility of all main measurement results.

Second digital display for additional data such as:

Insulation test voltage.

Insulation leakage current.

Supply frequency (when measuring volts).

Test mode eg. PI, DAR or TI (Timed mode).

Storage & Downloading Results

MIT430

The MIT430 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software. Data transfer is by Bluetooth.

NOTE: The receiving PC needs to have Bluetooth capability or a USB port fitted a Bluetooth receiver. Class II (10m) is acceptable.

Safety

Designed to be exceptionally safe to use, fast detecting circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Specifically, all instruments:
Meet the international requirements of IEC1010-2 and EN61557.

Live circuit detection inhibits insulation testing on circuits above 50 V.

Live circuit detection and test inhibit on continuity measurements.

Default display of live circuit voltage on all ranges.

Detection and inhibit functions operate even if the protection fuse has failed.

Suitable for use on CAT IV applications and supply voltages to 600 V


600 V CAT IV

All MIT400 instruments are designed to meet the safety requirements for use on CAT IV 600 V
INTRODUCING THE MIT400 SERIES
  
  
Legal | Privacy Find us on Facebook Follow us on Twitter Download Acrobat Reader Copyright © Megger Limited 2011

AVO, BIDDLE, MEGGER, MULTI-AMP, PAX Diagnostics, POWERDB, PROGRAMMA, and STATES are trademarks or registered trade marks of subsidiaries of Megger Group Limited

Legal | Privacy Find us on Facebook Follow us on Twitter Download Acrobat Reader Copyright © Megger Limited 2011

AVO, BIDDLE, MEGGER, MULTI-AMP, PAX Diagnostics, POWERDB, PROGRAMMA, and STATES are trademarks or registered trade marks of subsidiaries of Megger Group Limited