MIT480 series Product Page
|
|
Insulation testing from 50 V to 1000 V
Up to 200 GΩ range
75 V test inhibit
TRMS & DC Voltage measurement
Continuity testing at 200 mA or 20 mA
Capacitance measurement to 10 uF
Cable length by capacitance
The Megger MIT480 series of instruments has been developed specifically for the telecommunications industry. The insulation and continuity testers combine the latest range
of measurement techniques with new instrument design to provide a state-of-the-art tester that is compact and comfortable to hold.
The MIT480 series directly replaces the well-established BM80 product group, given greater functionality with simplified operation and a wider range of applications.
The Range:
MIT480: 50V, 100V tester
MIT481: 50V, 100V, 250V, 500V, 1000V tester
MIT485: As MIT481 with additional download of results via Bluetooth
Full comparison can be found on the datasheet.
STORAGE AND DOWNLOADING RESULTS
MIT481
The MIT481 is capable of saving test results for recall to the screen. A simple storage structure allows for a test number and screen results to be recalled individually.
MIT485
The MIT485 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software.
Data transfer is by Bluetooth, with the MIT485 Bluetooth transmitter being enabled when the Download mode is selected on the instrument.
NOTE: The receiving PC needs to have Bluetooth capability.
All quoted accuracies are at +20°C.
General
Insulation
Nominal test voltages
MIT480 50 V, 100 V
MIT481, 485 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation resistance range:
MIT480 10 GΩ
MIT481, 485 200 GΩ
Range Full Scale Accuracy
All ranges ±2% ±2 digits up to 100 MΩ.
Then:
1000 volts ±3% ±2 digits ±0.2% per GΩ
500 volts. ±3% ±2 digits ±0.4% per GΩ
250 volts. ±3% ±2 digits ±0.8% per GΩ
100 volts. ±3% ±2 digits ±2.0% per GΩ
50 volts. ±3% ±2 digits ±4.0% per GΩ
Analogue range 1 GΩ full scale
Short Circuit Current:
2 mA +0% -50%
Terminal voltage:
-0% +20% ±1 V
Test Current on load:
1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max.
EN61557 Operating range:
0,10 MGΩ to 1,00 GΩ
Leakage current range:
10 μA 2000 μA
Leakage current:
10% ±3 digits
Voltage display:
3% ±3 digits ±0.5% of rated voltage
Polarisation Index (PI):
10 min / 1minute ratio
Dielectric Absorption Ratio (DAR):
60 sec / 30 sec ratio
Notes:
(1) All ranges measure from 0,00 MΩ upwards.
(2) Above specifications only when high quality silicone leads are being used.
Continuity Measurement:
0,01Ω to 99,9Ω (0 to 100 Ω on analogue scale)
Accuracy:
±2% ±2 digits (0 to 100 Ω)
Open circuit voltage:
5 V ±1 V
Test current:
205 mA (-0 mA +20 mA) (0.01 Ω to 9.99 Ω)
20mA (±1 mA ) (10.0 Ω to 99.9 Ω)
Zero offset at probe tips:
0,10 Ω typical
Lead resistance zeroing:
Up to 9,99Ω
Buzzer:
Variable limit 1 Ω, 2 Ω, 5 Ω, 10 Ω, 20 Ω
Resistance
Measurement:
0,01 kΩ to 1000 kΩ (0 to 1 MΩ on analogue scale)
Accuracy:
±3% ±2 digits up to 50 kΩ
then ±2 digits
Open circuit voltage:
5 V ±1 V
Short circuit current:
1.5 mA ±0.2 mA
Voltage range:
0 to 600 V d.c. ±2% ±2 digits
10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
0 to 1000 V on Analogue scale
Unspecified input level 0 - 10 mV (40 to 400 Hz)
For non-sinusoidal waveforms additional specification
apply:
±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter:
Operates at >25 V a.c. or d.c.
on any range except OFF
Frequency:
40-450 Hz (40 Hz - 99,9 Hz)
±0.5% ±1 digit (100 Hz to 450 Hz)
Capacitance measurement
MIT481 and MIT485.
Measurement range:
100 pF to 10 μF
Accuracy:
± 5.0% ±2 digits
Distance by capacitance:
MIT481, MIT485
Arithmetic conversion from capacitance measurement on Default capacitance measurement: 50nF/km
Capacitance range:
40 nF/km to 60 nF/km
Result storage Capacity:
>1000 test results
Download:
Bluetooth wireless
Bluetooth Class:
Class II
Range:
up to 10 m
Power Supply:
5 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used.
Battery life:
2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions
Instrument:
220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument + case:
456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only:
590 gms, 775 gms with boot (20.73 oz., 27.22 oz.)
Instrument plus case:
1.75kg (3.86 lb)
Fuse:
Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection:
The instruments meet IEC 61010-1 to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C.:
In accordance with IEC 61326-.1
Temperate Effects
Temperature coefficient:
less than 0,1% per °C up to 1 GΩ
Environment
Operating range:
-20°C to +55°C
Operating humidity:
95% RH at 0ºC to +35ºC,
70% RH @ +35ºC to +55ºC
Storage temperature range:
-30 to +80°C
Calibration Temperature:
+20°C
Maximum altitude:
2000 m
Dust and water protection:
IP54 Protected against dust and splashing water
|
Replacement lead set
2-wire silicon lead set Red/Black
|
1001-858
|
|
|
|
TSP5 remote switch probe
Remote switch probe SP5 CATIV 600V (MIT400 series only)
|
1001-878
|
|
|
|
Rubber boot with stand
Protective rubber case to cover the MIT
|
5231-820
|
|
|
|
Hard case
Tough blow moulded plastic carry and storage case for MIT400 series testers. Will accommodate the instrument with and without protective rubber holster.
|
5410-420
|
|
|
|
Test and carry case
Carry pouch
|
6220-860
|
|
|
|
Probe cap (clear) bag of 20
clear caps to cover end of test leads
|
1000-562
|
|
|
|
Fused 500mA test lead set (Red/Black)
Fused 500mA test lead set (Reb/Black) with [prods and clips (NEW) right angled plugs
|
1002-015
|
| Keep up-to-date with the latest documentation for your device. |
| |
| Category |
Title |
Size |
|
| |
| Data Sheet |
The latest information data sheet |
| |
MIT480 Data Sheet
|
321 KB |
|
| User Guide |
| |
MIT480 User Guide
|
2,602 KB |
|
| |
|
|
|
INTRODUCING THE MIT480
Insulation testing from 50 V to 1000 V
Up to 200 GΩ range
75 V test inhibit
TRMS & DC Voltage measurement
Continuity testing at 200 mA or 20 mA
Capacitance measurement to 10 uF
Cable length by capacitance
The Megger MIT480 series of instruments has been developed specifically for the telecommunications industry. The insulation and continuity testers combine the latest range
of measurement techniques with new instrument design to provide a state-of-the-art tester that is compact and comfortable to hold.
The MIT480 series directly replaces the well-established BM80 product group, given greater functionality with simplified operation and a wider range of applications.
The Range:
MIT480: 50V, 100V tester
MIT481: 50V, 100V, 250V, 500V, 1000V tester
MIT485: As MIT481 with additional download of results via Bluetooth
Full comparison can be found on the datasheet.
STORAGE AND DOWNLOADING RESULTS
MIT481
The MIT481 is capable of saving test results for recall to the screen. A simple storage structure allows for a test number and screen results to be recalled individually.
MIT485
The MIT485 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software.
Data transfer is by Bluetooth, with the MIT485 Bluetooth transmitter being enabled when the Download mode is selected on the instrument.
NOTE: The receiving PC needs to have Bluetooth capability.
All quoted accuracies are at +20°C.
General
Insulation
Nominal test voltages
MIT480 50 V, 100 V
MIT481, 485 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation resistance range:
MIT480 10 GΩ
MIT481, 485 200 GΩ
Range Full Scale Accuracy
All ranges ±2% ±2 digits up to 100 MΩ.
Then:
1000 volts ±3% ±2 digits ±0.2% per GΩ
500 volts. ±3% ±2 digits ±0.4% per GΩ
250 volts. ±3% ±2 digits ±0.8% per GΩ
100 volts. ±3% ±2 digits ±2.0% per GΩ
50 volts. ±3% ±2 digits ±4.0% per GΩ
Analogue range 1 GΩ full scale
Short Circuit Current:
2 mA +0% -50%
Terminal voltage:
-0% +20% ±1 V
Test Current on load:
1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max.
EN61557 Operating range:
0,10 MGΩ to 1,00 GΩ
Leakage current range:
10 μA 2000 μA
Leakage current:
10% ±3 digits
Voltage display:
3% ±3 digits ±0.5% of rated voltage
Polarisation Index (PI):
10 min / 1minute ratio
Dielectric Absorption Ratio (DAR):
60 sec / 30 sec ratio
Notes:
(1) All ranges measure from 0,00 MΩ upwards.
(2) Above specifications only when high quality silicone leads are being used.
Continuity Measurement:
0,01Ω to 99,9Ω (0 to 100 Ω on analogue scale)
Accuracy:
±2% ±2 digits (0 to 100 Ω)
Open circuit voltage:
5 V ±1 V
Test current:
205 mA (-0 mA +20 mA) (0.01 Ω to 9.99 Ω)
20mA (±1 mA ) (10.0 Ω to 99.9 Ω)
Zero offset at probe tips:
0,10 Ω typical
Lead resistance zeroing:
Up to 9,99Ω
Buzzer:
Variable limit 1 Ω, 2 Ω, 5 Ω, 10 Ω, 20 Ω
Resistance
Measurement:
0,01 kΩ to 1000 kΩ (0 to 1 MΩ on analogue scale)
Accuracy:
±3% ±2 digits up to 50 kΩ
then ±2 digits
Open circuit voltage:
5 V ±1 V
Short circuit current:
1.5 mA ±0.2 mA
Voltage range:
0 to 600 V d.c. ±2% ±2 digits
10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
0 to 1000 V on Analogue scale
Unspecified input level 0 - 10 mV (40 to 400 Hz)
For non-sinusoidal waveforms additional specification
apply:
±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter:
Operates at >25 V a.c. or d.c.
on any range except OFF
Frequency:
40-450 Hz (40 Hz - 99,9 Hz)
±0.5% ±1 digit (100 Hz to 450 Hz)
Capacitance measurement
MIT481 and MIT485.
Measurement range:
100 pF to 10 μF
Accuracy:
± 5.0% ±2 digits
Distance by capacitance:
MIT481, MIT485
Arithmetic conversion from capacitance measurement on Default capacitance measurement: 50nF/km
Capacitance range:
40 nF/km to 60 nF/km
Result storage Capacity:
>1000 test results
Download:
Bluetooth wireless
Bluetooth Class:
Class II
Range:
up to 10 m
Power Supply:
5 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used.
Battery life:
2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions
Instrument:
220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument + case:
456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only:
590 gms, 775 gms with boot (20.73 oz., 27.22 oz.)
Instrument plus case:
1.75kg (3.86 lb)
Fuse:
Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection:
The instruments meet IEC 61010-1 to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C.:
In accordance with IEC 61326-.1
Temperate Effects
Temperature coefficient:
less than 0,1% per °C up to 1 GΩ
Environment
Operating range:
-20°C to +55°C
Operating humidity:
95% RH at 0ºC to +35ºC,
70% RH @ +35ºC to +55ºC
Storage temperature range:
-30 to +80°C
Calibration Temperature:
+20°C
Maximum altitude:
2000 m
Dust and water protection:
IP54 Protected against dust and splashing water
|
Replacement lead set
2-wire silicon lead set Red/Black
|
1001-858
|
|
|
|
TSP5 remote switch probe
Remote switch probe SP5 CATIV 600V (MIT400 series only)
|
1001-878
|
|
|
|
Rubber boot with stand
Protective rubber case to cover the MIT
|
5231-820
|
|
|
|
Hard case
Tough blow moulded plastic carry and storage case for MIT400 series testers. Will accommodate the instrument with and without protective rubber holster.
|
5410-420
|
|
|
|
Test and carry case
Carry pouch
|
6220-860
|
|
|
|
Probe cap (clear) bag of 20
clear caps to cover end of test leads
|
1000-562
|
|
|
|
Fused 500mA test lead set (Red/Black)
Fused 500mA test lead set (Reb/Black) with [prods and clips (NEW) right angled plugs
|
1002-015
|