CFL535F Product Page
|
|
20 km range at VF = 0.90
Intermittent fault location
Large backlit LCD Display
Dual cursor measurement
"TX Null" technology
No blocking filter required
Output pulse amplitude and width control
The Megger CFL535F series are a state of the art, monochrome and color, dual channel Time Domain Reflectometers, capable of identifying and locating a wide range
of faults on metallic cables
The CFL535F series has a minimum resolution of 0.1m and a maximum range of 20 km at VF=0.9 and 16 Km at 0.65 VF. The CFL535F can perform single or dual
channel measurements on a wide range of metallic cables. Active channels can be compared with each other or with previously stored traces from memory.
Differential channel measurements are possible and cross talk between channels can also be identified.
All results are displayed on a high resolution, QVGA color display*. Full contrast adjustment provides optimum display contrast in a variety of
ambient light conditions. (*CFL535FR)
3 Configurations Options
The CFL535F comes in three configurations:
CFL535F Monochrome primary cell A fully featured high resolution TDR with backlit monochrome display and powered by 8 x AA (LR6) batteries.
CFL535FM Monochrome rechargeable As the CFL535F but with a rechargeable NiMH battery pack and charger in place of the Dry cells.
CFL535FR color rechargeable As the CFL535FM but with a color high resolution display providing excellent trace separation in dual trace
modes. The unit is also powered by a rechargeable NiMH and includes battery charger.
Intermittent Mode.
An 'intermittent mode' continually updates and shows any transient reflections. Any intermittent fault leaves a permanent record on the display, capturing elusive faults.
Dual cursors.
The CFL535F can display either single or dual cursors. Single cursor mode displays the distance from the start of the cable to the cursor. In dual cursor mode the distance between faults can be measured.
Fast Find key.
One press of the find key automatically adjusts the range and gain and positions the cursor to the major event on the cable.
Tx Null.
Tx Null helps eliminate the 'dead zone' at the start of the displayed trace, normally obscured by the transmission pulse. By the adjusting the Tx Null the user can see these 'near end' faults more clearly.
Output Pulse Control.
Both the amplitude and width of the output pulse can be adjusted to provide the best possible reflection for accurate location of cable faults.
Interactive Help Screen.
A full graphical help screen is available with keyboard layout and individual key operation. At the press of a button.
Trace Storage.
15 internal trace memories provide for the storage and recall of test results. The traces can be recalled to the display for analysis or compared with an active display to aid in fault location. Alternatively the stored results can be downloaded to a computer, over the RS232 port, using the TraceMaster
software and RS232 lead provided.
Trace Master PC Software.
Trace Master provides download and upload facilities between the CFL and a computer. Traces can be individually selected, saved to a PC and annotated by the user. Historical information can be reviewed on the PC or recalled to the CFL for comparison with current measurements. Tracemaster is the ideal tool for cable documentation. Results can be printed from the computer for inclusion in documents.
Power Source.
The CFL535F series can be supplied as a standard battery powered unit or in a rechargeable version, as the CFL535FM or CFL535FR. Fitted with a NiMH rechargeable battery pack the CFL535FR and CFL535FM are supplied with the charger as standard.
Except where otherwise stated, this specification applies at an ambient temperature of 20° C.
Ranges
50 m, 100 m, 200 m, 400 m, 1 km, 2 km, 4 km, 8 km, 16 km (150 ft, 300 ft, 600 ft, 1200 ft, 3000 ft, 6000 ft, 12000 ft, 24000 ft, 48000 ft)
Resolution
0.1 m (4in.) up to 200 m (600 ft)
0.2 m (8 in.) up to 400 m (1200 ft)
0.1% of range above 400 m (1200 ft)
Measurement Accuracy
0.1% of Range
[Note – The measurement accuracy is for the indicated cursor position only and is conditional on the velocity being correct]
Input Impedance: 120 ½.
Input Protection: 300 V CATIII working, 415 V CATIII Phase to Phase
Output Pulse Amplitude
Nominal 3 V, 5 V and 14 Vpk to pk into an open circuit
Pulse width user selectable:
|
50m range:
|
7 ns, 20 ns, 40 ns,
|
|
150 ft
|
60 ns, 80 ns
|
|
100m range:
|
7 ns, 40 ns, 60 ns,
|
|
300 ft
|
80 ns, 100 ns
|
|
200m ranges:
|
80 ns, 100 ns
|
|
600 ft
|
140 ns, 200 ns
|
|
400 m range:
|
40 ns, 80 ns, 160 ns,
|
|
600 ft
|
140 ns, 200 ns
|
|
1km range:
|
80ns, 160ns, 260 ns,
|
|
3000 ft
|
500 ns, 1 ms
|
|
2km range:
|
160 ns, 260 ns,
|
|
6000 ft
|
500 ns, 1 ms, 2 ms
|
|
4km range:
|
240 ns, 500 ns,
|
|
12000 ft
|
1 ms, 2 ms, 4 ms
|
|
8km range:
|
500 ns, 1 ms, 2 ms,
|
|
24000 ft
|
4 ms, 8ms
|
|
16km range:
|
1 ms, 2 ms, 4 ms,
|
|
48000 ft
|
8 ms, 16 ms
|
(Default pulse width for each range underlined)
Gain: 0 to 90 dB in steps of 6 dB
Velocity Factor
Variable from 0.300 to 0.999 in steps of 0.001
TX Null: 0Ω to 120Ω
Screen Update Rate
Once per second or three times per second, (user selectable).
Power Down
Automatic after 5, 10 or 15 minutes with no keys pressed, (user selectable).
Backlight
Stays on for 1, 2 or 5 minutes when activated, (user selectable).
Communications Port
RS-232C compatible 1 start bit, 8 data bits, 1 stop bit and no parity, 19200 baud standard
Internal Memory: Storage capacity of 15 waveforms and data
Batteries
CFL535F: Eight LR6 (AA) type batteries, manganese-alkali or nickel-cadmium or nickel-metal-hydride cells.
CFL535FR: NiMH cell
CFL535FM: NiMH cell
Battery Charger
Supply voltage
European Version: 230 Vac ±10% 50 Hz
North American Version: 115 V a.c. ±10% 60 Hz
Safety
This instrument complies with IEC61010-1 for connection to live
systems up to 300V CAT III with fused leads.
EMC
The instrument will comply with EN 61326-1, classified as ‘class B’. If connected to a live domestic power supply, the operation of this instrument could cause interference with
other equipment connected to the same supply. To reduce this interference, select the lowest voltage and narrowest width pulse as consistent with accurate measurement. During
immunity tests there may be selfrecovering loss of function (i.e. Performance criterion B).
Mechanical
The instrument is designed for use indoors or outdoors and is rated to IP54.
Case Dimensions
250 L x 200 W x 110 D mm
(9.8 H x 7.9 W x 4.3 D in.)
Instrument Weight
1.5 kg (3.3lbs)
Case Material
ABS
Connectors
Two pairs of 4mm safety terminals.
9 way D-type connector for serial communication.
Display
320 x 240 pixel eight color backlight LCD.
Environmental
CFL535F
Operational Temperature: -15° C to +50° C (5° F to 122° F)
Storage Temperature: -20° C to +70° C (-4° F to 158° F)
CFL535FR
Operational Temperature: -15° C to +45° C (5° F to 113° F)
Storage Temperature: -20° C to +45° C (-4° F to 113° F)
Charging should not take place when the ambient temperature is less than 0° C (+32° F)
Humidity: <95% at +40° C non-condensing
Included Accessories
|
Test and carry pouch
A case to help protect and store your CFL535F.
|
6420-114
|
|
|
|
Serial data lead
For uploading your results to your PC.
|
25955-025
|
|
|
|
2 x miniature clip test lead set
|
6231-654
|
|
|
|
Carry strap for pouch
|
6220-611
|
|
|
|
TraceMaster software
|
6111-458
|
|
|
|
User guide
|
6172-662
|
Optional Accessories
|
Fused test lead set
|
6111-218
|
|
|
|
Bed of nails lead set
|
6231-653
|
|
|
|
Battery charger US mains
A US Mains charger for your CFL535FR/CFL535FM.
|
6121-539
|
INTRODUCING THE CFL535F SERIES
20 km range at VF = 0.90
Intermittent fault location
Large backlit LCD Display
Dual cursor measurement
"TX Null" technology
No blocking filter required
Output pulse amplitude and width control
The Megger CFL535F series are a state of the art, monochrome and color, dual channel Time Domain Reflectometers, capable of identifying and locating a wide range
of faults on metallic cables
The CFL535F series has a minimum resolution of 0.1m and a maximum range of 20 km at VF=0.9 and 16 Km at 0.65 VF. The CFL535F can perform single or dual
channel measurements on a wide range of metallic cables. Active channels can be compared with each other or with previously stored traces from memory.
Differential channel measurements are possible and cross talk between channels can also be identified.
All results are displayed on a high resolution, QVGA color display*. Full contrast adjustment provides optimum display contrast in a variety of
ambient light conditions. (*CFL535FR)
3 Configurations Options
The CFL535F comes in three configurations:
CFL535F Monochrome primary cell A fully featured high resolution TDR with backlit monochrome display and powered by 8 x AA (LR6) batteries.
CFL535FM Monochrome rechargeable As the CFL535F but with a rechargeable NiMH battery pack and charger in place of the Dry cells.
CFL535FR color rechargeable As the CFL535FM but with a color high resolution display providing excellent trace separation in dual trace
modes. The unit is also powered by a rechargeable NiMH and includes battery charger.
Intermittent Mode.
An 'intermittent mode' continually updates and shows any transient reflections. Any intermittent fault leaves a permanent record on the display, capturing elusive faults.
Dual cursors.
The CFL535F can display either single or dual cursors. Single cursor mode displays the distance from the start of the cable to the cursor. In dual cursor mode the distance between faults can be measured.
Fast Find key.
One press of the find key automatically adjusts the range and gain and positions the cursor to the major event on the cable.
Tx Null.
Tx Null helps eliminate the 'dead zone' at the start of the displayed trace, normally obscured by the transmission pulse. By the adjusting the Tx Null the user can see these 'near end' faults more clearly.
Output Pulse Control.
Both the amplitude and width of the output pulse can be adjusted to provide the best possible reflection for accurate location of cable faults.
Interactive Help Screen.
A full graphical help screen is available with keyboard layout and individual key operation. At the press of a button.
Trace Storage.
15 internal trace memories provide for the storage and recall of test results. The traces can be recalled to the display for analysis or compared with an active display to aid in fault location. Alternatively the stored results can be downloaded to a computer, over the RS232 port, using the TraceMaster
software and RS232 lead provided.
Trace Master PC Software.
Trace Master provides download and upload facilities between the CFL and a computer. Traces can be individually selected, saved to a PC and annotated by the user. Historical information can be reviewed on the PC or recalled to the CFL for comparison with current measurements. Tracemaster is the ideal tool for cable documentation. Results can be printed from the computer for inclusion in documents.
Power Source.
The CFL535F series can be supplied as a standard battery powered unit or in a rechargeable version, as the CFL535FM or CFL535FR. Fitted with a NiMH rechargeable battery pack the CFL535FR and CFL535FM are supplied with the charger as standard.
Except where otherwise stated, this specification applies at an ambient temperature of 20° C.
Ranges
50 m, 100 m, 200 m, 400 m, 1 km, 2 km, 4 km, 8 km, 16 km (150 ft, 300 ft, 600 ft, 1200 ft, 3000 ft, 6000 ft, 12000 ft, 24000 ft, 48000 ft)
Resolution
0.1 m (4in.) up to 200 m (600 ft)
0.2 m (8 in.) up to 400 m (1200 ft)
0.1% of range above 400 m (1200 ft)
Measurement Accuracy
0.1% of Range
[Note – The measurement accuracy is for the indicated cursor position only and is conditional on the velocity being correct]
Input Impedance: 120 ½.
Input Protection: 300 V CATIII working, 415 V CATIII Phase to Phase
Output Pulse Amplitude
Nominal 3 V, 5 V and 14 Vpk to pk into an open circuit
Pulse width user selectable:
|
50m range:
|
7 ns, 20 ns, 40 ns,
|
|
150 ft
|
60 ns, 80 ns
|
|
100m range:
|
7 ns, 40 ns, 60 ns,
|
|
300 ft
|
80 ns, 100 ns
|
|
200m ranges:
|
80 ns, 100 ns
|
|
600 ft
|
140 ns, 200 ns
|
|
400 m range:
|
40 ns, 80 ns, 160 ns,
|
|
600 ft
|
140 ns, 200 ns
|
|
1km range:
|
80ns, 160ns, 260 ns,
|
|
3000 ft
|
500 ns, 1 ms
|
|
2km range:
|
160 ns, 260 ns,
|
|
6000 ft
|
500 ns, 1 ms, 2 ms
|
|
4km range:
|
240 ns, 500 ns,
|
|
12000 ft
|
1 ms, 2 ms, 4 ms
|
|
8km range:
|
500 ns, 1 ms, 2 ms,
|
|
24000 ft
|
4 ms, 8ms
|
|
16km range:
|
1 ms, 2 ms, 4 ms,
|
|
48000 ft
|
8 ms, 16 ms
|
(Default pulse width for each range underlined)
Gain: 0 to 90 dB in steps of 6 dB
Velocity Factor
Variable from 0.300 to 0.999 in steps of 0.001
TX Null: 0Ω to 120Ω
Screen Update Rate
Once per second or three times per second, (user selectable).
Power Down
Automatic after 5, 10 or 15 minutes with no keys pressed, (user selectable).
Backlight
Stays on for 1, 2 or 5 minutes when activated, (user selectable).
Communications Port
RS-232C compatible 1 start bit, 8 data bits, 1 stop bit and no parity, 19200 baud standard
Internal Memory: Storage capacity of 15 waveforms and data
Batteries
CFL535F: Eight LR6 (AA) type batteries, manganese-alkali or nickel-cadmium or nickel-metal-hydride cells.
CFL535FR: NiMH cell
CFL535FM: NiMH cell
Battery Charger
Supply voltage
European Version: 230 Vac ±10% 50 Hz
North American Version: 115 V a.c. ±10% 60 Hz
Safety
This instrument complies with IEC61010-1 for connection to live
systems up to 300V CAT III with fused leads.
EMC
The instrument will comply with EN 61326-1, classified as ‘class B’. If connected to a live domestic power supply, the operation of this instrument could cause interference with
other equipment connected to the same supply. To reduce this interference, select the lowest voltage and narrowest width pulse as consistent with accurate measurement. During
immunity tests there may be selfrecovering loss of function (i.e. Performance criterion B).
Mechanical
The instrument is designed for use indoors or outdoors and is rated to IP54.
Case Dimensions
250 L x 200 W x 110 D mm
(9.8 H x 7.9 W x 4.3 D in.)
Instrument Weight
1.5 kg (3.3lbs)
Case Material
ABS
Connectors
Two pairs of 4mm safety terminals.
9 way D-type connector for serial communication.
Display
320 x 240 pixel eight color backlight LCD.
Environmental
CFL535F
Operational Temperature: -15° C to +50° C (5° F to 122° F)
Storage Temperature: -20° C to +70° C (-4° F to 158° F)
CFL535FR
Operational Temperature: -15° C to +45° C (5° F to 113° F)
Storage Temperature: -20° C to +45° C (-4° F to 113° F)
Charging should not take place when the ambient temperature is less than 0° C (+32° F)
Humidity: <95% at +40° C non-condensing
Included Accessories
|
Test and carry pouch
A case to help protect and store your CFL535F.
|
6420-114
|
|
|
|
Serial data lead
For uploading your results to your PC.
|
25955-025
|
|
|
|
2 x miniature clip test lead set
|
6231-654
|
|
|
|
Carry strap for pouch
|
6220-611
|
|
|
|
TraceMaster software
|
6111-458
|
|
|
|
User guide
|
6172-662
|
Optional Accessories
|
Fused test lead set
|
6111-218
|
|
|
|
Bed of nails lead set
|
6231-653
|
|
|
|
Battery charger US mains
A US Mains charger for your CFL535FR/CFL535FM.
|
6121-539
|
INTRODUCING THE CFL535F SERIES
|
|
|
 |
|
 |
|
|